BASIC INFO

Model

BTS4000-

5

V

10

mA

BatteryTestingSystem

SN:

CT-4008T

-5V10mA

-

164

Items

Values

Input AC

AC 220V/110V ±10% / 50Hz

Input power

25W

Resolution

AD:16bit; DA:16bit

Input impedance

≥1G Ω

Voltage

CV output range

25mV~5V

Min discharge voltage

-5V

Accuracy

± 0.05% FS

Stability

± 0.05% FS

Current

Output range/channel

Range1:5μA-1mA;Range2:1mA-5mA;Range3:5mA-10mA;

Accuracy

± 0.05% FS

CV cut-off current

Range1: 2μA; Range2: 0.01mA; Range3: 0.02mA

Stability

± 0.05% FS

Power

Output power/channel

0.05

W

Stability

± 0.1% FS

Time

Current response time

<500μs (10%FS~90%FS)

Working step time

≤(365*24)h/step Time format-00:00:00.000(h, m, s, ms)

Data record

Data record conditions

Min data record interval:100ms

Min voltage change: 10mV

Min current change: 2μA; 0.01mA; 0.02mA

Frequency

10Hz

Charge

Charge modes

CC, CV, CCCV, CP

Cut-off condition

Voltage, Current, Time, Capacity, -V

Discharge

Discharge modes

CC, CV, CCCV, CP, CR

Cut-off condition

Voltage, Current, Time, Capacity

Pulse

Charge

CC, CP

Discharge

CC, CP

Min pulse width

500ms

Pulse counts

Up to 32

Chg and Dschg switch

Supported

Cut-off condition

Voltage, Time

DCIR

Calculated DCIR values available in BTSDA

Cycle

Max cycles

65535

Max steps

254

Cycle nest

3

Protection

Safety protection

● Power-failure data protection

● Offline operation mode

● User-definedprotectionconditions,suchasupperandlower limited current/voltage, delay time, temperature, etc.

Channels feature

Independent pairs of closed loop for constant

Channels control mode

Independent control

Data acquisition method

Kelvin connection

Noise

<85dB

Database

MySQL

Communication

TCP/IP

Operating system

Windows 7/8/10 64 bit

Data export

EXCEL, TXT, CSV, PDF, Plot/Graph

Min. disk drive

500GB

Communication port

Ethernet port

Leak Current

0.005μA

Channels per unit

8

Operation and storage environment requirement

Items

Values

Operation environment temperature

0~40(Whenthetemperatureis25±10,theaccuracy offset causedbytemperature isless than50ppm/)

Storage environment temperature

-10~50

Operation environment humidity

≤70% RH(no moisture condensation)

Storage environment humidity

≤80% RH(no moisture condensation)

PREVIOUS:4 Paths Film Applicator
NEXT:5V20mA 8 Channel Battery Analyzer
Top footer
Contact usClose

Company: Zhengzhou TCH Instrument Co., Ltd

Contact: Dorry

Tel: +86 13526477203

Phone: 0086 13526477203

E-mail: tchinstrumenttch@163.com

Address: No.216, Changchun Road, High-Tech Zone, Zhengzhou City, Henan Province, China (450000)

Scan the qr code关闭
Qr code